CVE-2025-34196
Vasion Virtual Appliance Host hard-coded credentials
- Published29 Sept 2025
Description
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 25.1.102 and Application prior to 25.1.1413 (Windows client deployments) contain a hardcoded private key for the PrinterLogic Certificate Authority (CA) and a hardcoded password in product configuration files. The Windows client ships the CA certificate and its associated private key (and other sensitive settings such as a configured password) directly in shipped configuration files (for example clientsettings.dat and defaults.ini). An attacker who obtains these files can impersonate the CA, sign arbitrary certificates trusted by the Windows client, intercept or decrypt TLS-protected communications, and otherwise perform man-in-the-middle or impersonation attacks against the product's network communications. This vulnerability has been identified by the vendor as: V-2022-001 — Configuration File Contains CA & Private Key.
CVSS 3.1 breakdown
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HAffected products
Remediation
References
- https://help.printerlogic.com/saas/Print/Security/Security-Bulletins.htm
- https://help.printerlogic.com/va/Print/Security/Security-Bulletins.htm
- https://pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html#win-hardcoded-private-key
- https://www.vulncheck.com/advisories/vasion-print-printerlogic-hardcoded-printerlogic-ca-private-key-and-hardcoded-password
Related CVEs
Recent high-severity vulnerabilities sharing a weakness type.
Frequently asked
Is CVE-2025-34196 being actively exploited?
CVE-2025-34196 is not in the CISA KEV catalog. A public exploit reference exists, so treat it as exploitable. Its EPSS exploit probability is 0.48%.
How severe is CVE-2025-34196?
CVE-2025-34196 has a CVSS 3.1 base score of 9.8, rated critical. EPSS estimates a 0.48% probability of exploitation.
Which products are affected by CVE-2025-34196?
Affected products include Vasion Virtual Appliance Application, Vasion Virtual Appliance Host.
How do I fix CVE-2025-34196?
Upgrade affected software to a fixed version, for example Vasion Virtual Appliance Application 25.1.1413, Vasion Virtual Appliance Host 25.1.102 or later, then confirm no affected versions remain in your inventory.
How Secuno handles this
Secuno correlates vulnerabilities like CVE-2025-34196 against the real software inventory on every managed device, every day. Rather than a static severity, each match is scored in context: exploit availability, EPSS, the asset's exposure, and business criticality decide where it lands in the queue. If an affected version is present anywhere across your portfolio, it surfaces automatically with a prioritised remediation path.
Data from the NVD, CISA KEV catalog and FIRST EPSS. CVSS 3.1 base score shown where available.