Skip to content

CVE-2025-40949

Siemens Ruggedcom Rox Mx5000 Firmware command injection

9.1 CRITICALEPSS 0.67%
  1. Published12 May 2026

Description

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly sanitize user-supplied input in the Scheduler functionality of the Web UI, allowing commands to be injected into the task scheduling backend. This could allow an authenticated remote attacker to execute arbitrary commands with root privileges on the underlying operating system.

CVSS 3.1 breakdown

Attack vectorNetwork
Attack complexityLow
Privileges requiredHigh
User interactionNone
ScopeChanged
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Affected products

Siemens Ruggedcom Rox Mx5000 Firmware< 2.17.1
Siemens Ruggedcom Rox Mx5000re Firmware< 2.17.1
Siemens Ruggedcom Rox Rx1400 Firmware< 2.17.1
Siemens Ruggedcom Rox Rx1500 Firmware< 2.17.1
Siemens Ruggedcom Rox Rx1501 Firmware< 2.17.1
Siemens Ruggedcom Rox Rx1510 Firmware< 2.17.1
Siemens Ruggedcom Rox Rx1511 Firmware< 2.17.1
Siemens Ruggedcom Rox Rx1512 Firmware< 2.17.1
Siemens Ruggedcom Rox Rx1524 Firmware≤ 2.17.1
Siemens Ruggedcom Rox Rx1536 Firmware< 2.17.1
Siemens Ruggedcom Rox Rx5000 Firmware< 2.17.1

Remediation

Fixed in
Siemens Ruggedcom Rox Mx5000 Firmware≥ 2.17.1
Siemens Ruggedcom Rox Mx5000re Firmware≥ 2.17.1
Siemens Ruggedcom Rox Rx1400 Firmware≥ 2.17.1
Siemens Ruggedcom Rox Rx1500 Firmware≥ 2.17.1
Siemens Ruggedcom Rox Rx1501 Firmware≥ 2.17.1
Siemens Ruggedcom Rox Rx1510 Firmware≥ 2.17.1
Siemens Ruggedcom Rox Rx1511 Firmware≥ 2.17.1
Siemens Ruggedcom Rox Rx1512 Firmware≥ 2.17.1
Siemens Ruggedcom Rox Rx1536 Firmware≥ 2.17.1
Siemens Ruggedcom Rox Rx5000 Firmware≥ 2.17.1

Frequently asked

Is CVE-2025-40949 being actively exploited?

CVE-2025-40949 is not in the CISA KEV catalog. Its EPSS exploit probability is 0.67%.

How severe is CVE-2025-40949?

CVE-2025-40949 has a CVSS 3.1 base score of 9.1, rated critical. EPSS estimates a 0.67% probability of exploitation.

Which products are affected by CVE-2025-40949?

Affected products include Siemens Ruggedcom Rox Mx5000 Firmware, Siemens Ruggedcom Rox Mx5000re Firmware, Siemens Ruggedcom Rox Rx1400 Firmware, Siemens Ruggedcom Rox Rx1500 Firmware, Siemens Ruggedcom Rox Rx1501 Firmware, and 6 more.

How do I fix CVE-2025-40949?

Upgrade affected software to a fixed version, for example Siemens Ruggedcom Rox Mx5000 Firmware 2.17.1, Siemens Ruggedcom Rox Mx5000re Firmware 2.17.1, Siemens Ruggedcom Rox Rx1400 Firmware 2.17.1 or later, then confirm no affected versions remain in your inventory.

How Secuno handles this

Secuno correlates vulnerabilities like CVE-2025-40949 against the real software inventory on every managed device, as each hourly inventory arrives. Rather than a static severity, each match is scored in context: exploit availability, EPSS, the asset's exposure, and business criticality decide where it lands in the queue. If an affected version is present anywhere across your portfolio, it surfaces automatically with a prioritised remediation path.

Get Patch this first every Monday

Five vulnerabilities that matter this week, ranked on real exploitation. Plain language, one email, no spam.

You can unsubscribe with one click from every issue. We handle your details as described in our privacy policy.

Data from the NVD, CISA KEV catalog and FIRST EPSS. CVSS 3.1 base score shown where available.